41 research outputs found

    Inappropriate Implantable Cardioverter-Defibrillator Shocks Incidence, Predictors, and Impact on Mortality

    Get PDF
    ObjectivesThe purpose of this study was to assess the incidence, predictors, and outcome of inappropriate shocks in implantable cardioverter-defibrillator (ICD) patients.BackgroundDespite the benefits of ICD therapy, inappropriate defibrillator shocks continue to be a significant drawback. The prognostic importance of inappropriate shocks outside the setting of a clinical trial remains unclear.MethodsFrom 1996 to 2006, all recipients of defibrillator devices equipped with intracardiac electrogram storage were included in the current analysis and clinically assessed at implantation. During follow-up, the occurrence of inappropriate ICD shocks and all-cause mortality was noted.ResultsA total of 1,544 ICD patients (79% male, age 61 ± 13 years) were included in the analysis. During the follow-up period of 41 ± 18 months, 13% experienced ≥1 inappropriate shocks. The cumulative incidence steadily increased to 18% at 5-year follow-up. Independent predictors of the occurrence of inappropriate shocks included a history of atrial fibrillation (hazard ratio [HR]: 2.0, p < 0.01) and age younger than 70 years (HR: 1.8, p = 0.01). Experiencing a single inappropriate shock resulted in an increased risk of all-cause mortality (HR: 1.6, p = 0.01). Mortality risk increased with every subsequent shock, up to an HR of 3.7 after 5 inappropriate shocks.ConclusionsIn a large cohort of ICD patients, inappropriate shocks were common. The most important finding is the association between inappropriate shocks and mortality, independent of interim appropriate shocks

    Prognostic Importance of Atrial Fibrillation in Implantable Cardioverter-Defibrillator Patients

    Get PDF
    ObjectivesThis study aimed to assess the prevalence of different types of atrial fibrillation (AF) and their prognostic importance in implantable cardioverter-defibrillator (ICD) patients.BackgroundThe prevalence of AF has taken epidemic proportions in the population with cardiovascular disease. The prognostic importance of different types of AF in ICD patients remains unclear.MethodsData on 913 consecutive patients (79% men, mean age 62 ± 13 years) receiving an ICD at the Leiden University Medical Center were prospectively collected. Among other characteristics, the existence and type of AF (paroxysmal, persistent, or permanent) were assessed at implantation. During follow-up, the occurrence of appropriate or inappropriate device therapy as well as mortality was noted.ResultsAt implantation, 73% of patients had no history of AF, 9% had a history of paroxysmal AF, 7% had a history of persistent AF, and 11% had permanent AF. During 833 ± 394 days of follow-up, 117 (13%) patients died, 228 (25%) patients experienced appropriate device discharge, and 139 (15%) patients received inappropriate shocks. Patients with permanent AF exhibited more than double the risk of mortality, ventricular arrhythmias triggering device discharge, and inappropriate device therapy. Patients with paroxysmal or persistent AF did not show a significant increased risk of mortality or appropriate device therapy but demonstrated almost 3 times the risk of inappropriate device therapy.ConclusionsIn the population currently receiving ICD treatment outside the setting of clinical trials, a large portion has either a history of AF or permanent AF. Both types of AF have prognostic implications for mortality and appropriate as well as inappropriate device discharge

    EuroEco (European Health Economic Trial on Home Monitoring in ICD Patients): a provider perspective in five European countries on costs and net financial impact of follow-up with or without remote monitoring

    Get PDF
    Aim: Remote follow-up (FU) of implantable cardiac defibrillators (ICDs) allows for fewer in-office visits in combination with earlier detection of relevant findings. Its implementation requires investment and reorganization of care. Providers (physicians or hospitals) are unsure about the financial impact. The primary end-point of this randomized prospective multicentre health economic trial was the total FU-related cost for providers, comparing Home Monitoring facilitated FU (HM ON) to regular in-office FU (HM OFF) during the first 2 years after ICD implantation. Also the net financial impact on providers (taking national reimbursement into account) and costs from a healthcare payer perspective were evaluated. Methods and results: Atotal of 312 patients with VVI-or DDD-ICD implants from 17 centres in six EU countries were randomised to HMON or OFF, of which 303 were eligible for data analysis. For all contacts (in-office, calendar-or alert-triggered web-based review, discussions, calls) time-expenditure was tracked. Country-specific cost parameters were used to convert resource use into monetary values. Remote FU equipment itself was not included in the cost calculations. Given only two patients from Finland (one in each group) a monetary valuation analysis was not performed for Finland. Average age was 62.4 +/- 13.1 years, 81% were male, 39% received a DDD system, and 51% had a prophylactic ICD. Resource use with HM ON was clearly different: less FU visits (3.79 +/- 1.67 vs. 5.53 +/- 2.32; P < 0.001) despite a small increase of unscheduled visits (0.95 +/- 1.50 vs. 0.62 +/- 1.25; P < 0.005), more non-office-based contacts (1.95+3.29 vs. 1.01 +/- 2.64; P < 0.001), more Internet sessions (11.02 +/- 15.28 vs. 0.06 +/- 0.31; P < 0.001) and more in-clinic discussions (1.84 +/- 4.20 vs. 1.28 +/- 2.92; P < 0.03), but with numerically fewer hospitalizations (0.67 +/- 1.18 vs. 0.85 +/- 1.43, P = 0.23) and shorter length-of-stay (6.31 +/- 15.5 vs. 8.26 +/- 18.6; P = 0.27), although not significant. For the whole study population, the total FU cost for providers was not different for HM ON vs. OFF [mean (95% CI): (sic)204 169-238) vs. (sic)213 (182-243); range for difference ((sic)-36 to 54), NS]. From a payer perspective, FU-related costs were similar while the total cost per patient (including other physician visits, examinations, and hospitalizations) was numerically (but not significantly) lower. There was no difference in the net financial impact on providers [profit of (sic)408 (327-489) vs. (sic)400 (345-455); range for difference ((sic)-104 to 88), NS], but there was heterogeneity among countries, with less profit for providers in the absence of specific remote FU reimbursement (Belgium, Spain, and the Netherlands) and maintained or increased profit in cases where such reimbursement exists (Germany and UK). Quality of life (SF-36) was not different. Conclusion: For all the patients as a whole, FU-related costs for providers are not different for remote FU vs. purely in-office FU, despite reorganized care. However, disparity in the impact on provider budget among different countries illustrates the need for proper reimbursement to ensure effective remote FU implementation

    Five-year safety and efficacy of leadless pacemakers in a Dutch cohort

    Get PDF
    BACKGROUND: Adequate real-world safety and efficacy of leadless pacemakers (LPs) have been demonstrated up to 3 years after implantation. Longer-term data are warranted to assess the net clinical benefit of leadless pacing.OBJECTIVE: The purpose of this study was to evaluate the long-term safety and efficacy of LP therapy in a real-world cohort.METHODS: In this retrospective cohort study, all consecutive patients with a first LP implantation from December 21, 2012, to December 13, 2016, in 6 Dutch high-volume centers were included. The primary safety endpoint was the rate of major procedure- or device-related complications (ie, requiring surgery) at 5-year follow-up. Analyses were performed with and without Nanostim battery advisory-related complications. The primary efficacy endpoint was the percentage of patients with a pacing capture threshold ≤2.0 V at implantation and without ≥1.5-V increase at the last follow-up visit.RESULTS: A total of 179 patients were included (mean age 79 ± 9 years), 93 (52%) with a Nanostim and 86 (48%) with a Micra VR LP. Mean follow-up duration was 44 ± 26 months. Forty-one major complications occurred, of which 7 were not advisory related. The 5-year major complication rate was 4% without advisory-related complications and 27% including advisory-related complications. No advisory-related major complications occurred a median 10 days (range 0-88 days) postimplantation. The pacing capture threshold was low in 163 of 167 patients (98%) and stable in 157 of 160 (98%).CONCLUSION: The long-term major complication rate without advisory-related complications was low with LPs. No complications occurred after the acute phase and no infections occurred, which may be a specific benefit of LPs. The performance was adequate with a stable pacing capture threshold.</p
    corecore